1. Peak and rms values
A sinusoidal supply: , (India: 50 Hz, ω ≈ 314 rad s⁻¹). The average current over a cycle is zero, but the average of is 1/2, so power is delivered.
rms value: the steady value giving the same average heating: , so and . AC meters read rms; “220 V mains” is rms (peak ≈ 311 V).
- v = V₀ sin ωt
Formulas
- rms values
Key terms
- rms value
The steady (DC) value that produces the same average heating in a resistor; I₀/√2 for a sinusoid.
2. AC through R, L and C; reactance
| Element | Opposition | Phase of I relative to V | Average power |
|---|---|---|---|
| R | R | in phase | |
| L | lags by π/2 | 0 | |
| C | leads by π/2 | 0 |
- Inductor: gives .
- Capacitor: .
- (blocks high frequencies, passes DC); (blocks DC, passes high frequencies).
- Phasors: arrows of length equal to the peak value rotating anticlockwise at ω; projections give instantaneous values; angles give phase differences.
- voltage across L
- current in L (lags by π/2)
Formulas
- Reactances
Key terms
- Inductive reactance
X_L = ωL, the opposition of an inductor to AC.
- Capacitive reactance
X_C = 1/ωC, the opposition of a capacitor to AC.
- Phasor
A rotating vector representing a sinusoidal quantity.
3. Series LCR circuit and resonance
Same current through all; voltages add as phasors: .
: inductive (V leads I); : capacitive (I leads V).
Resonance: at , . Then (minimum), (maximum), φ = 0. Smaller R gives a sharper resonance — used in radio tuning. Voltages across L and C at resonance can be much larger than the supply voltage.
- small R: sharp peak
- larger R: broad, lower peak
Formulas
- Impedance
- Resonance
Key terms
- Impedance
Total opposition of an AC circuit, Z = V/I.
- Resonance
Condition X_L = X_C at which a series LCR circuit carries maximum current.
4. Power, power factor and wattless current
Average power ; power factor (series LCR).
- Pure R: cos φ = 1. Pure L or C: cos φ = 0 (energy stored and returned each cycle). At resonance: 1.
- Only resistance dissipates: .
- Wattless current: the component , 90° out of phase with V, delivers no average power but still causes loss in the supply lines. Capacitors are added to inductive loads (motors) to raise the power factor.
Formulas
- Average power
Key terms
- Power factor
cos φ, the ratio of real power to the product V_rms I_rms.
- Wattless current
The component of current 90° out of phase with the voltage; it consumes no average power.
5. AC generator and transformer
AC generator: a coil (N turns, area A) rotates at ω in field B: , , peak (largest when the coil’s plane is parallel to B). Slip rings and brushes connect the coil to the circuit. Mechanical energy → electrical energy.
Transformer: primary and secondary on a laminated soft-iron core; works by mutual induction, AC only.
- Ideal: ; power in = power out.
- Step-up () for transmission; step-down for distribution and chargers.
- Losses: copper (, thick wires), flux leakage (interleaved windings), hysteresis (soft iron), heating of the core by induced currents (laminated core).
Formulas
- Generator
- Ideal transformer
Key terms
- Transformer
A device that changes an alternating voltage using mutual induction between two coils on a common core.
- Turns ratio
N_s/N_p, equal to V_s/V_p for an ideal transformer.
Exam tips
- Mains figures are rms; peak = √2 × rms.
- CIVIL: in C, I leads V; in L, V leads I.
- Series LCR: draw I as reference; Z from the impedance triangle; at resonance Z = R, I max, in phase.
- Power: P = VI cos φ; wattless current I sin φ.
- Transformer: turns-ratio relations; list losses with remedies.