1. Electrical energy and power
- Energy: (joule). In a resistor it all becomes heat (Joule heating).
- Power: (watt; 1 W = 1 J s⁻¹; 1 kW = 1000 W; 1 MW = 10⁶ W).
- Use when the current is common (series) and when the voltage is common (parallel, mains).
| Known | Use |
|---|---|
| V and I | P = VI |
| I and R | P = I²R |
| V and R | P = V²/R |
Formulas
- Electrical energy
- Electrical power
Key terms
- Electrical power
The rate at which electrical energy is converted into other forms by an appliance.
- Watt
The power of an appliance that converts one joule of electrical energy every second.
2. Power rating of an appliance
- “1000 W, 220 V”: when connected to 220 V the appliance converts 1000 J of electrical energy every second.
- From the rating: and (R stays the same if the voltage changes).
- On a different voltage: , so .
- For the same voltage, a higher-power appliance has a lower resistance.
| Rating | Current | Resistance |
|---|---|---|
| 100 W, 220 V | 0.45 A | 484 Ω |
| 1000 W, 220 V | 4.55 A | 48.4 Ω |
| 2200 W, 220 V | 10 A | 22 Ω |
Formulas
- Resistance from the rating
- Power at another voltage
Key terms
- Power rating
The power an appliance converts when it is connected to its stated (rated) voltage.
3. The kilowatt hour and electricity bills
- 1 kWh = energy used by a 1 kW appliance in 1 hour J; the commercial unit of electrical energy.
- Units = power (kW) × time (h) × number of appliances × days.
- Cost = units × rate per unit.
- Energy use depends on power and hours of use; efficient devices (LED lamps) save units.
| Appliance | Power | Hours | kWh |
|---|---|---|---|
| Electric iron | 1 kW | 1 | 1 |
| LED lamp | 10 W | 100 | 1 |
| Geyser | 2 kW | 0.5 | 1 |
Formulas
- Commercial unit
- Energy in kWh
Key terms
- Kilowatt hour
The electrical energy consumed by an appliance of power one kilowatt working for one hour; it equals 3.6 million joules.
4. Power distribution and house wiring
- Generated at about 11 kV → stepped up to about 132 kV → transmission lines → stepped down to 33 kV, then 11 kV, then 220 V for houses. High voltage means low current, so less I²R loss in the lines.
- Supply in India: 220 V, 50 Hz AC; live wire at 220 V, neutral at about 0 V.
- From the pole: company fuse (in the live wire) → kWh meter → main switch (double pole: breaks live and neutral) → distribution board (a fuse or MCB for each circuit) → circuits.
- Appliances are connected in parallel: each gets 220 V and can be switched independently.
| Stage | Voltage |
|---|---|
| Generation | 11 kV |
| Transmission | 132 kV or more |
| House supply | 220 V |
Key terms
- Distribution board
The box after the main switch from which separate circuits, each with its own fuse or MCB, are taken to different parts of a house.
- Double pole main switch
A switch that breaks both the live and the neutral wires at the same time.
5. Fuse, MCB and the ring main
- Fuse: a short thin wire of an alloy of low melting point (tin–lead), joined in series in the live wire; it melts when the current exceeds its rating (overload or short circuit). Rating: just above the normal current .
- MCB (miniature circuit breaker): an automatic switch that trips when the current is too large and can simply be reset.
- Switches and fuses in the live wire: when off or blown, the appliance is disconnected from the high potential.
- Ring main: a cable (L, N, E) runs from the distribution board round the rooms and back to the board; protected by a 30 A fuse or MCB; sockets in parallel; current reaches each socket by two paths, so a thinner cable will do.
| Feature | Fuse | MCB |
|---|---|---|
| Action | Wire melts | Switch trips |
| After a fault | Must be replaced | Reset by hand |
| Placed in | Live wire | Live wire |
Formulas
- Normal current, for choosing a fuse
Key terms
- Fuse
A safety device: a short wire of low melting point in the live wire that melts and breaks the circuit when the current exceeds a set value.
- Ring main
A household circuit in which a cable loop starting and ending at the distribution board feeds sockets connected in parallel along it.
6. Two-way switch, three-pin plug, earthing and safety
- Two-way switch: a common terminal and two contacts. Staircase wiring: live → common of S1; two strap wires join the contacts of S1 and S2; common of S2 → lamp → neutral. Lamp on when both levers are on the same strap; either switch changes it.
- Three-pin plug: earth pin longer (connects first, disconnects last) and thicker (cannot enter the L or N hole).
- Earthing: the metal body is joined to a copper plate buried in moist ground; a live-to-body fault sends a large current to earth, so the fuse melts.
- Colour code (new): live brown, neutral light blue, earth green / green-yellow (old: red, black, green).
- Safety: correct fuse rating, no overloading, switch off the mains for repairs, dry hands, earthed metal appliances, good insulation.
| Wire | New colour | Old colour |
|---|---|---|
| Live | Brown | Red |
| Neutral | Light blue | Black |
| Earth | Green or green-yellow | Green |
Key terms
- Earthing
Connecting the metal body of an appliance to the earth through a thick wire and a buried plate, so that a fault current flows to the ground.
- Two-way switch
A switch with one common terminal that can be connected to either of two contacts, used in pairs to control one lamp from two places.
Exam tips
Common mistakes
- Using watts and minutes when finding kWh.
- Assuming an appliance gives its rated power on any voltage.
- Putting the fuse or switch in the neutral wire.
- Choosing a fuse rating far above the normal current.
- Giving only one reason for the shape of the earth pin.
How marks are usually awarded
- Bills: units per appliance (1), total units (1), cost (1).
- Wiring: correct order of parts and the function of each.
- Safety: a reason for each device, linked to the live wire or to earth.