Electrical Power, Energy and Household Circuits — Notes

6 sections 6 min readBeta

1. Electrical energy and power

  • Energy: W=QV=VIt=I2Rt=V2tRW = QV = VIt = I^{2}Rt = \dfrac{V^{2}t}{R} (joule). In a resistor it all becomes heat (Joule heating).
  • Power: P=Wt=VI=I2R=V2RP = \dfrac{W}{t} = VI = I^{2}R = \dfrac{V^{2}}{R} (watt; 1 W = 1 J s⁻¹; 1 kW = 1000 W; 1 MW = 10⁶ W).
  • Use I2RI^{2}R when the current is common (series) and V2/RV^{2}/R when the voltage is common (parallel, mains).
Table of which power formula to use for each pair of known quantities
KnownUse
V and IP = VI
I and RP = I²R
V and RP = V²/R

Formulas

  • Electrical energy
    W=VIt=I2Rt=V2tRW = VIt = I^{2}Rt = \dfrac{V^{2}t}{R}
  • Electrical power
    P=VI=I2R=V2RP = VI = I^{2}R = \dfrac{V^{2}}{R}

Key terms

Electrical power

The rate at which electrical energy is converted into other forms by an appliance.

Watt

The power of an appliance that converts one joule of electrical energy every second.

2. Power rating of an appliance

  • “1000 W, 220 V”: when connected to 220 V the appliance converts 1000 J of electrical energy every second.
  • From the rating: I=PVI = \dfrac{P}{V} and R=V2PR = \dfrac{V^{2}}{P} (R stays the same if the voltage changes).
  • On a different voltage: P′=V′2RP' = \dfrac{V'^{2}}{R}, so P′P=(V′V)2\dfrac{P'}{P} = \left(\dfrac{V'}{V}\right)^{2}.
  • For the same voltage, a higher-power appliance has a lower resistance.
Table of three power ratings with their current and resistance
RatingCurrentResistance
100 W, 220 V0.45 A484 Ω
1000 W, 220 V4.55 A48.4 Ω
2200 W, 220 V10 A22 Ω

Formulas

  • Resistance from the rating
    R=V2PR = \dfrac{V^{2}}{P}
  • Power at another voltage
    P′P=(V′V)2\dfrac{P'}{P} = \left(\dfrac{V'}{V}\right)^{2}

Key terms

Power rating

The power an appliance converts when it is connected to its stated (rated) voltage.

3. The kilowatt hour and electricity bills

  • 1 kWh = energy used by a 1 kW appliance in 1 hour =1000×3600=3.6×106= 1000 \times 3600 = 3.6 \times 10^{6} J; the commercial unit of electrical energy.
  • Units = power (kW) × time (h) × number of appliances × days.
  • Cost = units × rate per unit.
  • Energy use depends on power and hours of use; efficient devices (LED lamps) save units.
Table of three ways of using one kilowatt hour
AppliancePowerHourskWh
Electric iron1 kW11
LED lamp10 W1001
Geyser2 kW0.51

Formulas

  • Commercial unit
    1 kWh=3.6×106 J1\ \text{kWh} = 3.6 \times 10^{6}\ \text{J}
  • Energy in kWh
    units=P (kW)×t (h)\text{units} = P\,(\text{kW}) \times t\,(\text{h})

Key terms

Kilowatt hour

The electrical energy consumed by an appliance of power one kilowatt working for one hour; it equals 3.6 million joules.

4. Power distribution and house wiring

  • Generated at about 11 kV → stepped up to about 132 kV → transmission lines → stepped down to 33 kV, then 11 kV, then 220 V for houses. High voltage means low current, so less I²R loss in the lines.
  • Supply in India: 220 V, 50 Hz AC; live wire at 220 V, neutral at about 0 V.
  • From the pole: company fuse (in the live wire) → kWh meter → main switch (double pole: breaks live and neutral) → distribution board (a fuse or MCB for each circuit) → circuits.
  • Appliances are connected in parallel: each gets 220 V and can be switched independently.
Table of voltages at three stages of power distribution
StageVoltage
Generation11 kV
Transmission132 kV or more
House supply220 V

Key terms

Distribution board

The box after the main switch from which separate circuits, each with its own fuse or MCB, are taken to different parts of a house.

Double pole main switch

A switch that breaks both the live and the neutral wires at the same time.

5. Fuse, MCB and the ring main

  • Fuse: a short thin wire of an alloy of low melting point (tin–lead), joined in series in the live wire; it melts when the current exceeds its rating (overload or short circuit). Rating: just above the normal current I=P/VI = P/V.
  • MCB (miniature circuit breaker): an automatic switch that trips when the current is too large and can simply be reset.
  • Switches and fuses in the live wire: when off or blown, the appliance is disconnected from the high potential.
  • Ring main: a cable (L, N, E) runs from the distribution board round the rooms and back to the board; protected by a 30 A fuse or MCB; sockets in parallel; current reaches each socket by two paths, so a thinner cable will do.
Table comparing a fuse and a miniature circuit breaker
FeatureFuseMCB
ActionWire meltsSwitch trips
After a faultMust be replacedReset by hand
Placed inLive wireLive wire

Formulas

  • Normal current, for choosing a fuse
    I=PVI = \dfrac{P}{V}

Key terms

Fuse

A safety device: a short wire of low melting point in the live wire that melts and breaks the circuit when the current exceeds a set value.

Ring main

A household circuit in which a cable loop starting and ending at the distribution board feeds sockets connected in parallel along it.

6. Two-way switch, three-pin plug, earthing and safety

  • Two-way switch: a common terminal and two contacts. Staircase wiring: live → common of S1; two strap wires join the contacts of S1 and S2; common of S2 → lamp → neutral. Lamp on when both levers are on the same strap; either switch changes it.
  • Three-pin plug: earth pin longer (connects first, disconnects last) and thicker (cannot enter the L or N hole).
  • Earthing: the metal body is joined to a copper plate buried in moist ground; a live-to-body fault sends a large current to earth, so the fuse melts.
  • Colour code (new): live brown, neutral light blue, earth green / green-yellow (old: red, black, green).
  • Safety: correct fuse rating, no overloading, switch off the mains for repairs, dry hands, earthed metal appliances, good insulation.
Table of the new and old colour codes for house wiring
WireNew colourOld colour
LiveBrownRed
NeutralLight blueBlack
EarthGreen or green-yellowGreen

Key terms

Earthing

Connecting the metal body of an appliance to the earth through a thick wire and a buried plate, so that a fault current flows to the ground.

Two-way switch

A switch with one common terminal that can be connected to either of two contacts, used in pairs to control one lamp from two places.

Exam tips

Common mistakes

  • Using watts and minutes when finding kWh.
  • Assuming an appliance gives its rated power on any voltage.
  • Putting the fuse or switch in the neutral wire.
  • Choosing a fuse rating far above the normal current.
  • Giving only one reason for the shape of the earth pin.

How marks are usually awarded

  • Bills: units per appliance (1), total units (1), cost (1).
  • Wiring: correct order of parts and the function of each.
  • Safety: a reason for each device, linked to the live wire or to earth.